After finishing the installation of floor, it goes to the upper structure. Even there is concrete, it doesn’t affect other structure and the installation of cladding material. Along with BFS specialized floor supporting system, it achieves excellent acoustic and insulation performance.
Dead Loads Used for Design | |||
Load Type | Sub Total(kpa) | Total Load | |
Sheet Roof | 0.48mm Sheet | 0.08 | |
OSB Cladding | 0.06 | ||
Accessories | 0.06 | 0.20kpa | |
Tile Roof | Terra Cotta Tiles | 0.56 | |
OSB Cladding | 0.06 | ||
Accessories | 0.1 | ||
Total | 0.72kpa | ||
Truss SelfWeight | 0.06kN/m | ||
Ceiling Weight | Plasterboard | 0.1 | |
Accessories | 0.06 | ||
Total | 0.16kpa | ||
Floor SelfWeight | Floor Framing | 0.12 | |
Floor Sheeting | 0.15 | ||
Accessories | 0.22 | ||
Total | 0.49kpa | ||
Wall SelfWeight | Plasterboard | 2x0.13 | |
Wall Weight | 0.08 | ||
OSB Cladding | 2x0.06 | ||
Accessories | 0.02 | ||
Total | 0.48kpa |
Roof Snow Load | |
Location | Load |
Intermediate Roof Snow Load | 0.00kpa |
0.85kpa | |
Eave Snow Load | 0.00kpa |
1.20kpa |
Basic Wind Speeds and Factors | |
Item | Load |
Permissible Wind Speed | 40 and 45m/s |
Design Wind Pressure for 40m/s | 0.864kpa |
Design Wind Pressure for 45m/s | 1.093kpa |
External roof coefficients | -0.90, +0.40 |
Internal roof coefficients | +0.20, -0.30 |
External roof coefficients at eaves | -1.8 |
Internal roof coefficients at eaves | 0.2 |
External wall coefficients | 0.7 |
Internal wall coefficients | -0.3 |
External wall coefficients at corners | -1.3 |
Internal wall coefficients at corners | 0.2 |